Pre-analysis of a dataset
A solver answering infeasible names no cause, and an Irreducible
Inconsistent Subsystem, when the solver offers one, speaks of rows and columns
rather than of areas, resources and years. pommes.pre_analysis()
computes, from the parameters alone and without building the model, the
necessary conditions of feasibility below and the statistics they rest on
(issue #1).
from pommes import check_inputs, pre_analysis
model_parameters = check_inputs(model_parameters)
result = pre_analysis(model_parameters) # logs every finding
print(result.report())
result.summary() # per area, resource and year: demand vs. maximum supply
result.emissions # per year: emissions no dispatch avoids vs. carbon_goal
Run it before a solve, or after an infeasible one.
What is checked
Capacities. A vintage invested in year_inv is alive in year_op
when year_inv <= year_op < end_of_life. The installed capacity of a year
lies between the minimum investments of the vintages surely alive (with early
decommissioning, only the one invested that very year) and the maximum
investments of all the vintages alive, further bounded by
conversion_power_capacity_min and conversion_power_capacity_max.
Imposed investments above the allowed total, or a required total the allowed
investments cannot reach, are infeasible. A vintage counts only if it has a
planning variable: without early decommissioning, its end of life must be a
year_dec label, and an investment imposed on a vintage that has none is
reported as a warning, since the model drops it silently. A retrofit converts
source vintages that retire in the retrofit year, so a target holds at most
its ratio times every source investment made before the year; the source
keeps its vintages until that year, and its minimum capacity with them.
Power. Hour by hour, per area and resource, the demand – with the floor of the flexible demand – against the largest supply the data allow: every conversion capacity at its upper bound and availability, times its positive factors; every combined unit in the mode giving the most of the resource; storage discharging at full power; every transport link flowing in; imports at their annual ceiling. The same over all areas, where transport cancels out (except on links leaving from outside the areas) – the only bound left when the transport capacities are unbounded.
Energy. The same per year, where the annual ceilings bind
(*_max_yearly_production, net_import_max_yearly_energy_import) and
storage gives back at most what it took, its cycle closing within the year.
Emissions. Two lower bounds on the emissions of a year, the larger of
which holds: the emitting units with a must-run, at their minimum capacity;
and the emitting supply needed where the sources emitting nothing fall short,
hour by hour, at the lowest emission per unit of the resource. Net of the
largest negative emissions, against carbon_goal.
Fossil exit. From fossil_exit_year (2050 by default) on, the power and
energy balances again without any fossil source. By default a source is
fossil when it emits: imports with a positive
net_import_total_emission_factor – at the hours and conditions it is
positive only –, conversion technologies and combined modes with a positive
emission factor. fossil_resources and
fossil_technologies name them instead; a name that is not a label of the
dataset raises a ValueError. The check also names the fossil
units forced to run (a must-run on an imposed capacity) or imposed and still
installed, and says when the data do not impose the exit at all.
The exit is imposed in a year and operating condition when the carbon goal
there is zero, nothing can remove carbon, and fossil means emitting: a
shortfall is then an infeasibility. Otherwise it is a warning – the exit set
as an objective cannot be met with the data given. fossil_exit_year=None
disables the check.
Reading the findings
Every bound is a relaxation of the model: a conversion is counted with its output and never with the input it needs, so a resource is never short of what produces it; ramps, production groups and the energy capacity that limits how long storage can discharge are left out. Hence:
infeasible: the model cannot be solved, whatever the solver.warning: it can, but not as one may expect. For theadequacy_*checks, only by shedding load (at least the amount given); for thefossil_exit_*checks, the exit cannot happen although the data do not impose it, which says nothing of load shedding; forcapacity, an investment bound the model drops.info: worth reading, not a fault – an imposed fossil capacity, an exit the data do not impose.
A dataset without any finding can still be infeasible. The solver’s own
diagnostic (Gurobi’s IIS, linopy’s print_infeasibilities) or a run
with load shedding and spillage allowed takes over from there.
All quantities are in the units of the adequacy row: demand per time step
for power, the units of the annual ceilings for energy and emissions.